300-625 Actual Questions Answers PDF 100% Cover Real Exam Questions
300-625 Exam questions and answers
2. Implementation
Weightage – 35%
The second domain is an extensive one. It is focused on topics like the implementation of Fibre Channel port channels, Fibre Channel protocol services, Name service, and Cisco Fabric Services. It also checks the ability to implement FCoE, including FCoE Initialization Protocol. Besides, it also throws light on concepts like Priority flow control, Enhanced transmission selection, Data Center Bridging Exchange/Link Level Discovery Protocol. The configuration and implementation of VSAN extensions, and NPV and NPIV are involved in this module too.
Preparation Steps to Follow
If you have already reviewed the exam blueprint, you understand that there is a lot of work to be done. Finding useful and credible information sources is a crucial point for every candidate striving to pass the Cisco 300-625 test on the first try. However, this is precisely why the vendor offers many study options that you can use to prepare with great deliberation. All in all, you can explore the following prep resources:
1. Enroll for the Official Training Course
The Configuring Cisco MDS 9000 Series Switches v3.5 course is designed to facilitate the individuals for the 300-625 exam thanks to the full coverage of the topics tested. It deals with the switches from Cisco and teaches about their proper implementation, management, and troubleshooting. After the completion of this course, the students will know how to develop scalable SANs. Moreover, they will be able to work with virtual storage area networks, role-based access control, and n-port virtualization. Regarding arrangement, this is a 4-day instructor-led training course with hands-on lab practice. It is available for anyone who wants to take the DCMDS program virtually or as a self-study variant. But it’s worth noting that the learners must be aware of the fundamentals of data storage, networking protocols, routing, and switching before enrolling for this course.
NEW QUESTION 28
A storage administrator is enabling DH-CHAP for the first time on a Fibre Channel fabric. Which condition must the administrator consider while configuring this feature?
- A. Enabling DH-CHAP protocol feature is unsupported on FCIP interfaces.
- B. All switches on the fabric must be configured for the same password.
- C. The MD5 hash must be used if TACACS+ or RADIUS authentication for FCSP is enabled.
- D. NTP must be configured on all devices or the configuration fails.
Answer: C
Explanation:
Section: Implementation
NEW QUESTION 29
Drag and drop the boot issues from the left onto the correct solutions on the right.
Answer:
Explanation:
Explanation:
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/6-x/troubleshooting/guide/b_Cisco_Nexus_9000_Series_NX-OS_Troubleshooting_Guide/b_Cisco_Standalone_Series_NX-OS_Troubleshooting_Guide_chapter_01.html#reference_7F7ADD86A12B4D2389E478280BE037A0
NEW QUESTION 30
Which two steps are mutual between Cisco secure boot and UEFI secure boot? (Choose two.)
- A. operating system
- B. kemel
- C. hardware anchor
- D. bootloader
- E. microloader
Answer: A,D
Explanation:
Section: Deployment
NEW QUESTION 31
A storage administrator wants to enable NPV in a Fibre Channel edge switch. Which configuration is supported in this mode?
- A. Dynamic Port VSAN Membership
- B. local switching of east-west traffic
- C. E Port connectivity to the core switch
- D. Cisco Fabric Services distribution over Fibre Channel
Answer: D
Explanation:
Section: Implementation
NEW QUESTION 32
Which item is a component of Cisco DCNM?
- A. Cisco DCNM for Cisco UCS Manager
- B. Cisco DCNM FabricPath license
- C. Cisco DCNM for SAN and Cisco DCNM for LAN
- D. Cisco DCNM for B- and C-Series servers
Answer: C
NEW QUESTION 33
Which configuration is needed to enable manual ESP mode for Fibre Channel TrustSec on Cisco MDS switches?
- A. MDS(config)# interface fc 1/1
MDS(config-if)# fcsp mode gcm
MDS(config-if-fcsp)# fcsp esp manual - B. MDS(config)# interface fc 1/1
MDS(config-if)# fcsp esp manual - C. MDS(config)# fcsp esp manual
- D. MDS(config)# interface fc 1/1
MDS(config-if)# fcsp esp manual
MDS(config-if-fcsp)# mode gcm
Answer: B
NEW QUESTION 34
Refer to the exhibit.
The san-user must configure FSPF on the VSAN 500, but fails. An operator with network administrative rights must authorize the san-user to perform this work. Which configuration must the operator apply?
- A. MDS-A(config)# role name sangroup
MDS-A(config-role)# vsan policy deny
MDS-A(config-role-vsan)# permit vsan 500 - B. MDS-A(config)# role name sangroup
MDS-A(config-role)# rule 2 permit config feature vsan - C. MDS-A(config)# role name sangroup
MDS-A(config-role)# rule 4 permit config feature fspf - D. MDS-A(config)# role name sangroup
MDS-A(config-role)# no rule 2
Answer: A
Explanation:
Section: Management and Monitoring
NEW QUESTION 35
A network engineer is configuring a Cisco MDS switch for FCoE. Which two conditions must be considered during the implementation phase? (Choose two.)
- A. FCoE is already enabled on a Cisco MDS switch.
- B. VLAN 1 or the native VLAN can be mapped to an FCoE VSAN.
- C. On the Cisco MDS, the MTU is set equal to 2112.
- D. The QoS policy must be identical to other Cisco FCoE switches in the network.
- E. On Cisco MDS switches, system-defined class maps for class-FCoE and class-default are enabled but can be deleted.
Answer: D,E
NEW QUESTION 36
Refer to the exhibit.
Refer to the exhibits A storage network engineer activates a zoneset on MDS-A and verifies the successful activation (Exhibit 1) The engineer is then notified that there is a SAN outage (Exhibit 2) What is the cause of the outage?
- A. Another network engineer activated the zoneset ZoneSetMDS-B-VSAN100 command on another switch in the fabric.
- B. Another network engineer activated zoneset ZoneSetMDS-B-VSAN100 on MDS-A.
- C. Another network engineer issued the zone mode enhanced vsan 100 command on another switch in the fabric.
- D. Another network engineer issued the zone default-zone permit vsan 100 command on another switch in the fabric.
Answer: B
NEW QUESTION 37
Which two components are required for successful MDS USB POAP (Choose two.)
- A. ENTERPRISE_PKG license
- B. system and kickstart images
- C. script named poap_script pl
- D. NTFS formatted USB drive
- E. USB drive in port 1
Answer: B,C
Explanation:
Section: Deployment
NEW QUESTION 38
Drag and drop the items from the left onto the correct descriptions on the right. Not all items are used.
Answer:
Explanation:
NEW QUESTION 39
Which feature on MDS platforms ensures that the code that is running on the hardware platform is authentic and unmodified, while also validating the BIOS to eliminate any rootkits?
- A. UEFI Secure Boot
- B. Cisco Secure Boot
- C. Secure Unique Device Identifier
- D. BIOS Secure Boot
Answer: A
NEW QUESTION 40
Refer to the exhibit.
Refer to the exhibit. An engineer is configuring Inter-VSAN routing for two Cisco MDS switches. The FSPF cost between the switches is 500, and the Cisco MDS core virtuahzes an IVR NAT domain as shown. Which statement about the topology is correct?
- A. The MDS-Core simulates an IVR NAT and increases the cost to 501.
- B. The MDS-Core simulates an IVR NAT. and the FSPF cost is 500.
- C. The MDS-Core simulates an IVR NAT and increases the cost to 600.
- D. The MDS-Core simulates an IVR NAT and decreases the cost to 400.
Answer: B
NEW QUESTION 41
Which three features are part of Cisco DCNM for SAN Advanced Edition? (Choose three.)
- A. federation and VSAN scoping
- B. event lookup
- C. VM-aware discovery and path analysis
- D. fabric performance monitoring
- E. VSAN zoning
Answer: A,C,D
NEW QUESTION 42
Which port mode is used on an NPV device to connect to an NPIV core switch?
- A. F
- B. E
- C. N
- D. NP
Answer: C
NEW QUESTION 43
A storage network engineer must install and configure a new MDS switch in a data center network. Which two statements about available choices during the MDS switch initial setup are correct? (Choose two.)
- A. The engineer can configure the default switch port trunk mode.
- B. The secure password standard is required.
- C. The engineer can configure the default zone policy.
- D. The engineer can choose what will be the administrator account.
- E. The engineer does not have the choice to enable or disable full zoneset distribution.
Answer: C,D
NEW QUESTION 44
Refer to the exhibit.
Which configuration change improves the ability of the link to recover from frame loss?
- A. Increase the send buffer size to 15000 KB.
- B. Disable PMTU discovery.
- C. Increase the reset timeout.
- D. Enable selective acknowledgment.
Answer: D
Explanation:
Section: Implementation
NEW QUESTION 45
A storage network engineer is implementing disk-array data replication between two SAN environments in two different data centers not connected via Fibre Channel. Which SAN switch feature must be implemented?
- A. IVR
- B. VSAN scoping
- C. zoning merge over LAN
- D. FCIP
Answer: D
NEW QUESTION 46
Drag and drop the FLOGI parameters from the left onto the descriptions from which they were derived on the right.
Answer:
Explanation:
Explanation:
https://www.cisco.com/en/US/docs/storage/san_switches/mds9000/sw/rel_3_x/configuration/guides/cli_3_2/npv.html
NEW QUESTION 47
Refer to the exhibit. Which command is used to determine which switch has the lock?
- A. show flogi database
- B. show zoneset active
- C. show zone status
- D. show fcs ie vsan
Answer: C
NEW QUESTION 48
......
To Sum Up
Use all the variety of training resources to get ready for the Cisco 300-625 test and prove your knowledge of Cisco switches. With its corresponding CCNP Data Center certification, you’ll have way more career opportunities. Achieve new heights by stepping at this path today!
Dumpexams 300-625 Exam Practice Test Questions : https://www.dumpexams.com/300-625-real-answers.html